Loop Powered Level Transmitter – Range 25 feet (7.62 Meters)
This ultrasonic level transmitter is intrinsically safe (IS) and CSA rated for Class I Division 1 hazardous areas in the US and Canada. It has a maximum range of 25 feet (7.62 meters) and is typically used for tank level measurement but can also be used for other hazardous area applications such as measuring the roll diameter on coating machinery. The transmitter sensing element is chemically resistant and the electrical connection is a two-wire loop-powered 4-20 mA output. The SafeSonic 25-L is pre-calibrated from 1 and 25 feet but can be user-calibrated to other ranges using optional accessories.
Level Transmitter | Cable Length | |
![]() |
Part Number SSPC-L25-6 SSPC-L25-10 SSPC-L25-20 SSPC-L25-30 SSPC-L25-50 SSPC-L25-100 |
(potted-in) 6-ft 10-ft 20-ft 30-ft 50-ft 100-ft |
![]() |
Part Number |
Connector Only |
Configuration Accessories | ||
Part Number UA-RCD-L |
Description (see Accessories links below) Remote Configuration Device for SafeSonic 25-L when used with SenixSAFE-L software. |
SafeSonic ultrasonic level transmitters for hazardous environments can be configured to provide volume outputs for non-linear tank shapes or flow outputs for flumes and weirs. If you need sensor capabilities not listed here please contact us.
Range | 1 to 25 feet (0.31 to 7.62 meters) |
Accuracy | +/-0.25% of detected range |
Output | 4-20 mA, 2-wire loop powered |
Temperature | -40° to 140° F (-40° to 60° C) |
Humidity | 0 to 100% operating |
Protection | NEMA-4X, IP65 |
Transducer | Ruggedized piezoelectric |
Compensation | Internal temperature compensation |
Update Rate | 15 Seconds avg. (SenixSAFE-L adjustable) |
Hazardous Area Certifications | Class I, Div. 1, Groups C & D, T3 Class I, Zone 0, AEx iA IIB, T3 Ex ia IIB, T3 |
Top Mount | 3/4 in NPT thread |
Bottom Mount | 2-in NPT thread |
Materials | Transducer: PVDF (Kynar); Housing: PC/PBT |
Total Weight | 1.5 lbs. (0.68 kg) (with 6-ft cable) |
Specifications are subject to change without notice.