Senix TSPC
Family - Outputs Available by Model |
||||||
| MODELS ▼ |
▼ Available Outputs ▼ | |||||
| SenixVIEW Output Selection ▼ | 0-10 VDC 0-5 VDC |
4-20 mA Current Loop |
Solid State Switch | Serial Data RS-232 | Serial Data RS-485 | |
| see notes 1 & 2 | see note 3 | see note 4 | See note 5 | see note 6 | ||
|
TSPC-30S1 Series - Max range 4 m (14 ft.) |
||||||
| TSPC-30S1-232 |
Output #1 choices ► (user selected) |
1 Current sourcing * |
1 NPN or PNP |
2 wires (+ GND) |
||
| Output #2
choices ► (user selected) |
1 Voltage * |
1 NPN or PNP |
||||
| Asterisk (*) indicates default output selections | ||||||
| TSPC-30S1-485 | Output choices same as TSPC-30S1-232 above. | 2 wires (+ GND) |
||||
|
TSPC-15S Series - Max range 9.1 meters (30 ft.) |
||||||
| TSPC-15S-232 |
All outputs simultaneous ► |
1 | 1 sourcing 1 sinking |
2 NPN or PNP |
2 wires (+ GND) |
|
| TSPC-15S-485 |
All outputs simultaneous ► |
1 | 1 sourcing 1 sinking |
2 NPN or PNP |
2 wires (+ GND) |
|
|
TSPC-21S Series - Max range 15.2 meters (50 feet) |
||||||
| TSPC-21S-232 |
All outputs simultaneous ► |
1 | 1 sourcing 1 sinking |
2 NPN or PNP |
2 wires (+ GND) |
|
| TSPC-21S-485 |
All outputs simultaneous ► |
1 | 1 sourcing 1 sinking |
2 NPN or PNP |
2 wires (+ GND) |
|
| Notes: (1) TSPC-30S series sensors have two SenixVIEW selectable outputs. The defaults are 0-10 VDC and 4-20 mA. Output #1 choices are current loop (sourcing) or NPN switch or PNP switch. Output #2 choices are voltage or NPN or PNP switches. (2) TSPC-15S and TSPC-21S series sensors have multiple simultaneous outputs including voltage, two current loops, two switches and serial data (type defined by model). Switch types are selectable as PNP or NPN using SenixVIEW. (3) The voltage output range is pushbutton selectable as either 0-5 VDC or 0-10 VDC. Default: 0-10 VDC (4) Current loop output in TSPC-30S1 models is current sourcing. Independent current sinking and current sourcing outputs are provided in TSPC-15S and TSPC-21S series. (5) Switches can be selected as NPN (sinking) or PNP (sourcing) using SenixVIEW. (6) The RS-232 and RS-485 serial data interfaces of TSPC and LVL Family products are defined by the model number as RS-232 or RS-485. All sensors use the modbus protocol to communicate with SenixVIEW or user equipment. Senix offers an OCX control software so users can easily integrate TSPC and LVL sensor communications into their systems. Serial data can also be set to an ASCII streaming output for simpler applications. |
||||||